Vacuum aggregates
Vacuum aggregates
2 Pump units
AV40/25 | ||
Pumping speed*) | m3 / h | 40 |
Buffer tank volume | dm3 | 250 |
Vacuum pump type | - | AT21A |
Power installed | kW | 1,5 |
Noise level | dB (A) | 70 |
Inlet diameter | mm | 40 |
Outlet diameter | mm | 25 |
Weight | kg | 220 |
Power supply | V/Hz | 3 x 400/50 |
Final vacuum in buffer tanks | hPa/% | 30 / 97 |
Vacuum setting scope | % | 0 - 96 |
*) at atmospheric pressure
AV40 | ||
Pumping speed*) | m3 / h | 40 |
Buffer tank volume | dm3 | 750 |
Vacuum pump type | - | AT21A |
Power installed | kW | 1,5 |
Noise level | dB (A) | 70 |
Inlet diameter | mm | 40 |
Outlet diameter | mm | 25 |
Weight | kg | 375 |
Power supply | V/Hz | 3 x 400/50 |
Final vacuum in buffer tanks | hPa/% | 30 / 97 |
Vacuum setting scope | % | 0 - 96 |
AV63 | ||
Pumping speed*) | m3 / h | 63 |
Buffer tank volume | dm3 | 750 |
Vacuum pump type | - | AT40B |
Power installed | kW | 1,5 |
Noise level | dB (A) | 67 |
Inlet diameter | mm | 40 |
Outlet diameter | mm | 40 |
Weight | kg | 395 |
Power supply | V/Hz | 3 x 400/50 |
Final vacuum in buffer tanks | hPa/% | 30 / 97 |
Vacuum setting scope | % | 0 - 96 |
AV100 | ||
Pumping speed*) | m3 / h | 100 |
Buffer tank volume | dm3 | 1000 |
Vacuum pump type | - | AT63B |
Power installed | kW | 3 |
Noise level | dB (A) | 70 |
Inlet diameter | mm | 40 |
Outlet diameter | mm | 40 |
Weight | kg | 550 |
Power supply | V/Hz | 3 x 400/50 |
Final vacuum in buffer tanks | hPa/% | 30 / 97 |
Vacuum setting scope | % | 0 - 96 |
AV160 | ||
Pumpgeschwindigkeit*) | m3 / h | 160 |
Behältervolumen | dm3 | 1600 |
Typ der installierten Pumpen | - | AT100B |
Installierte Leistung | kW | 6 |
Lärmpegel | dB (A) | 70 |
Eingangsdurchmesser | mm | 40 |
Ausgangsdurchmesser | mm | 40 |
Gewicht der Zentraleinheit | kg | 710 |
Stromversorgung | V/Hz | 3 x 400/50 |
Endvakuum in Behältern | hPa/% | 30 / 97 |
Einstellungsumfang im Vakuumbereich | % | 0 - 96 |
*) at atmospheric pressure
AV300 | ||
Pumping speed*) | m3 / h | 300 |
Buffer tank volume | dm3 | 1600 |
Vacuum pump type | - | AT160B |
Power installed | kW | 8 |
Noise level | dB (A) | 75 |
Inlet diameter | mm | 60 |
Outlet diameter | mm | 60 |
Weight | kg | 955 |
Power supply | V/Hz | 3 x 400/50 |
Final vacuum in buffer tanks | hPa/% | 30 / 97 |
Vacuum setting scope | % | 0 - 96 |
AV500 | ||
Pumping speed*) | m3 / h | 500 |
Buffer tank volume | dm3 | 3000 |
Vacuum pump type | - | AT250B |
Power installed | kW | 11 |
Noise level | dB (A) | 80 |
Inlet diameter | mm | 60 |
Outlet diameter | mm | 60 |
Weight | kg | 1160 |
Power supply | V/Hz | 3 x 400/50 |
Final vacuum in buffer tanks | hPa/% | 30 / 97 |
Vacuum setting scope | % | 0 - 96 |
*) at atmospheric pressure
Description
INTENDED USE
Vacuum aggregates are intended for use in central vacuum installations, in particular in the health service services objects such as hospitals, clinics, out-patient clinics, health centers, emergency medical aid stations etc. Vacuum aggregates can also be used in all other central vacuum plants in industry; in such case the anti-bacterial filters are replaced with standard air filters.
ADVANTAGES
- low-noise operation,
- no special requirements for rooms in where the units are installed,
- no foundation is required,
- the unit operates correctly during long vacuum-drawing operation,
- wide range of vacuum thresholds adjustment,
- the units can be linked in batteries to operate in parallel,
- tanks can be made of stainless steel,
- the observation vessel can be cleaned without any need to switch the unit off,
- the anti-bacterial filters can be replaced without any need to switch the unit off,
- a microprocessor controller with vacuum measurement allows for unit remote control operation,
- compact design allows for the unit to be transported through standard door openings,
- modern and compact design of vacuum pumps fitted in the unit.
STEROWNIK AGREGATU
- programming of vacuum thresholds in the vacuum installation (0 ÷ 98%)
- maintaining the vacuum at the pre-set level
- continuous vacuum measurement within the range of 1000 ÷ 1 mbar
- time of pump operation recording
- electric supply phase correctness control
- assuring “circular” pump operation cycle
- automatic pump switching in case of higher vacuum demand
- indication of excess the alarm pressure level
- indication of breakdown, if any
- protected against inputting of any undesirable settings changes
- can be connected to computer monitoring
- keyboard liquid-proof protection – IP67 class